TRACER SYSTEM TQ-F

SKU: 987 Categories: ,
 

Description

MOBILE DISCHARGE MEASUREMENT SYSTEM FOR TURBULENT RIVERS WITH UNKNOW CROSS-SECTION PROFILE – FLUORESCENCE TRACER

The discharge measurement is performed by using the well-established tracer-dilution method and is especially suitable for high volumes of water. The system can be deployed in turbulent rivers, creeks or waters for which data regarding the cross-section profile are not available or unknown. It is used a fluorescent material as tracer. After insertion of a known amount of tracer material two optical fluorescence probes automatically determine the discharge. This way high plausibility and accurate results can be guaranteed.

FIELDS OF APPLICATION

The TQ-Tracer system is especially suitable for fast-flowing, turbulent waters with complex cross sections, for example mountain streams, small brooks, tributaries or even fish passes. Equally the TQ-tracer works very well in shallow rivers where most other instruments fail to get reliable results or cannot be used any more at all. The TQ is used particularly in hydrometry as well as by consulting engineers, civil engineers, and hydropower plant operators monitoring the discharge, for control measurements or for project evaluations.

IMPLEMENTATION

The tracer dilution method can be applied for discharge measurement in all waters in which a thorough mixing of the tracer takes place. High turbulences, alternating cross sections and stones promote the mixing process and therefore are helpful. For particularly turbulent waters and very high flow velocities there is a TQ-version available where the sensitive probes are protected with a robust reinforcement. The user-friendly software TQ-Commander leads comfortably through the measurement and provides a full measuring report after the measurement.

Specifications

GENERAL

  • Measuring principle tracer dilution method with instantaneous feed
  • Application all discharge volumes

TQ-AMP (MEASUREMENT DEVICE WITH BLUETOOTH-TRANSMISSION)

  • Memory capacity none (data storage in the receiving device)
  • Transmission interval 1 second
  • Data transfer Bluetooth class 1 (transmission range up to 100m)
  • Operating temperature -20 … +60 °C
  • Protection IP66
  • Energy supply 3x 1.5 V batteries, size AA or 3x 1.5 V / 2500 mAh NiMH batteries, size AA
  • Operation time 25 hrs (with 3x 2500 mAh batteries)
  • Recharging time approx. 10 hrs

PROBES

  • Probe type fluorescence probe
  • Measurement range Fluorescein/Rhodamine: 0 … 50 μg/l (ppb)
  • Resolution 0.05 μg/l (ppb)
  • Operating temperature 0 … +50 °C
  • (Further types of probes for different tracer substances available upon request.)

ACCESSORIES INCLUDED

  • Pipette 500 μl
  • Jars bottle for calibration solution, measuring cup stainless steel 750 ml, measuring cup 500 ml, volumetric flask 500 ml
  • Others USB memory stick (software and documentation), USB Bluetooth adapter, recharger, protection- and weighting armour
  • TQ-Commander (software) PC-Version Windows XP, Windows Vista or Windows 7 up to 10